Search

Digital Tachometer, RPM Meter, Digital LED Tachometer, Green 4 Digit LED Motor Tachometer RPM Speed Measure Meter NPN Hall Proximity Switch Sensor for Lathes, Conveyor Belts

KWD 8.500

Brand
Naroote
Weight
84 g
1 +

Special Features

  • 【LED DISPLAY】0.56inch 4-digit LED screen clearly display RPM readings in green
  • 【DIGITAL LED TACHOMETER】Come with 3 wire NPN Hall Proximity Switch Sensor
  • 【9999RPM】Revolution speed measurement up to 9999rpm
  • 【STURDY AND FUNCTIONAL】High precision, quick response, stable and reliable
  • 【APPLICATIONS】8-24V wide supply voltage, suitable for various applications of RPM speed measurement

Description

1. 0.56inch 4-digit LED screen clearly display RPM readings in green.
2. Come with 3 wire NPN Hall Proximity Switch Sensor.
3. Revolution speed measurement up to 9999rpm.
4. High precision, quick response, stable and reliable.
5. 8-24V wide supply voltage, suitable for various applications of RPM speed measurement.

Spec:
Item Type: Tachometer
Operating Voltage: DC 8-24V, 40mA
Display: 0.56inch green LED, 4 digit reading
Measuring Range: 10-9999rpm
Measuring Accuracy: ±0.1%, reading±1digit
Display Refresh Rate: >3 times/sec
Overrange Display: Display 1 or -1 in the first digit position, none in the last three digit positions
Hall Proximity Switch Type: NPN NO
Tachometer Size: 79x26x43mm / 3.11x1.02x1.69in

PackageList:
1 x LED Tachometer
1 x Hall Proximity Switch
1 x Round Magnet
1 x Cable

Notice:
1. Connect the plug correctly according to the wiring diagram.
2. The Hall switch is an NPN normally open type, and the detection distance of the Hall switch needs to be within 10 mm. The Hall switch is installed with a diameter of 12 mm and a wire length of 1m or less.
3. Avoid strong electromagnetic interference, the measurement wire is best to use shielded wire or twisted pair wire.
4. The counter signal and the clear signal input switch or circuit should be as close as possible to the terminals of the counter to make the signal line as short as possible.
5. Avoid the same tube or stranded wiring with strong electric wires or power wires to avoid unnecessary interference. If necessary, please use shielded wires, and the shielding layer is connected to the counting terminal +.
6. It is not recommended to use mechanical switches or micro switches, because their life is relatively short, it is easy to miscount after a long time; if using mechanical switches or micro switches, please try to use better quality one, so as not to m
7.Please note

Related Items


{"error":"Error","cart_limit":"You have too many items in your cart.","prod_limit":"You cannot add any more of this item"}