Production Name:Motor Start Capacitor, Volume: 124-149 MFD, Withstand Voltage: 250V AC 50/60 Hz, Shape: Round
US style and professinal start capacitor for single phase motor, no PCBs inisde
OverView Size: 1-13/16 x 3-3/8 in(46x85mm),Dia*Height, check your original capacitor size before replacement(also there is small size 36*36*70mm/1.4*1.4*2.75 inch type used)
Housed in a rugged phenolic resin case and strong body,PCB free
Each pole has 2 pcs quick dsconnect terminals, convient for fast replacement
Description
124-149 Motor Start Capacitor
Volume: 124-149 mfd
Overview Size:1-13/16 x 3-3/8 in(46x85mm)
Remark:
1.Please pay attention to capacitor's size, normally bigger vollume bigger housing size, also higher withstand voltage bigger housing size
2.Normally one start capacitor and another run capacitor in single phase control systems
3.Start capacitor only use once when motor starts, yet run capacitor always run
4.Don't start motor frequently, it will lead more heat and damaged capacitor
5.Motor cann't start,please also check moving system smootly or not, resisstance force bigger or not, overload or not
6.Please wait for capacitor to released power, then begin to repair, or use one 1 M ohm or more resistance to release power