Maxmartt Adjustable Time Delay Relay Module Motor Control Delay Timing Timer Relay Module DC 5/6/9/12V with 2A Drive Current and Reverse Polarity Motor Control

KWD 3

Brand
Maxmartt
Weight
15 g
1 +

Special Features

  • Compatible with operating voltage DC 5-12V (5V 6V 9V 12V)
  • Reverse polarity control supported for efficient motor operation
  • Low operating current of 5V with 4mA in forward and 36mA in reverse; 12V with 6mA in forward and 44mA in reverse
  • Supports maximum load current of 2A and load voltage DC 1-48V or AC 85-265V
  • Adjustable time delay function for enhanced control

Description

Description:
Operating voltage: DC 5-12V(5V 6V 9V 12V)
Operating current: 5V, forward 4mA, reverse: 36mA;
                              12V, forward 6mA, reverse: 44mA
Load voltage: DC 1-48V or AC 85-265V
Load current: Max 2A
Forward max time: 5000 seconds, 0.1 seconds step
Reverse max time: 5000 seconds, 0.1 seconds step
Size: 54*22*15mm / 2.12*0.87*0.59in
Weight: Approx. 15g
How to use:
VIN connected to the positive of power supply , GND connected to the negative of power supply;
P+ connected to the positive of motor power supply, P- connected to the negative of motor power supply;
M + & M- connected to both ends of the motor
After power, D1 flashes for 3 times, D2 off, M+ output positive, M- output negative, motor forward; After a time delay T1, D2 on, M+ output negative, M- output positive, motor reversal; After a time delay T2, D2 off, M+ output positive, M- output negative, motor forward; And so on.
T1: motor forward delay time, default 0.1-5000 seconds adjustable (step 0.1 seconds)
T2: motor reverse delay time, default 0.1-5000 seconds adjustable (step 0.1 seconds)
By "Time multiple selection" setting, the maximum delay is up to 40,000 seconds
How to Set Up:
After power on, D1 3 blinks, enter the "work mode"
D2 on Reversal, D2 off Forward
Press and hold the key for 2 seconds, D1 on, enter the "setup mode"
D2 off, It's forward "setup mode"
In forward "setup mode", continuously trigger KEY twice, D1 off, enter "Standby timer mode"
In the "Standby timer mode" , trigger KEY to start timing(enter "Timing Mode")
D1 flashing means it is timing("Timing Mode")
Trigger KEY again to stop the clock(exit "Timing Mode")
D1 flashing time is forward time(T1)
Press and hold the Key for 2 seconds, D2 on, enter the Reverse "setup mode"
In Reverse "setup mode", continuously trigger key twice, D1 off, enter "Standby timer mode"
In the "Standby timer mode", trigger KEY start timing(enter "Timing Mode")
D1 flashing means it is timing("Timing Mode")
Trigger KEY again to stop the clock(exit "Timing Mode")
D1 flashing time is Reverse time(T2)
So far, forward time(T1) and reverse time(T2) is set up
Re-power in "work mode"