DROK 40-400V 100A AC Meter
Parameter:
Voltage
Measure Range: AC 40-400V
Display Resolution: when
when ≥100V, displays as 110V
Measure Precision: ±1%
Current
Measure Range: AC 0-100A
Display Resolution: when
when
when =100A, displays as 100A
Notice: when you use this meter to measure current, the current should be higher than 0.02A
Measure Precision: ±1%
Power
Measure Range: 0-22Kw
Display Resolution: when
When
When
When
When ≥10000W, displays as 22.0kw
Notice: when you use this meter to measure power, the current should be higher than 2.2W
Measure Precision: ±1%
Power Factor
Measure Factor: 0-1
Display Resolution: as 1.00PF
Other Functions:
Back Light
Press the key to turn on/off back light
Calibration
Step 1: Long press the key for 3 second until the screen flashes
Step 2: when the digit flashing circularly, it refers to: voltage high digit→voltage middle digit→voltage low digit→→voltage decimal point→ampere high digit→ampere middle digit→ampere low digit→ampere decimal point. Short press the key to adjust the value of flashing digit.
Step 3: Long press the key for 3 second, the screen displays “pass” which means the parameter saved.
Notice: Calibration must operate under pure resistance (PF=1.00) load situation, or the error value would be higher than before.