Specification
Shell Material: AL6061
Weight: 4g
Dimension: 21*15*8.8mm
Operating Voltage: 3.7~8.4V
Current Drain: 20mA/6V
Operating temperature: -10℃+50℃
Dual Gain Mode: Normal / Sensitive Mode
Input Siginal: PWM(50-333Hz) / SANWA SHR; SSR / FUTABA S.BUS
Output Signal: 1520uS (50Hz/333Hz) / SANWA SSR
Control System: PID Control System
Input & Output Plug: JST1.5mm (attached the signal input cable to connect with receiver)
Function of Switch
EPA(Travel Setting)
Press the switch to power on, orange slow flash, enter into servo travel set mode, rotate the remote control steering to make the servo stop at the required position(to left or right). Short press the switch, orange light fast flash 2 times, red solid light, then yellow-green slow flash, it means current travel has been saved. Rotate the remote control steering again to make the servo stop at another required positon, short press the switch, orange light fast flash 2 times, then solid light, witch means it has been saved as well. After 2 seconds gyro enter into initialization automatically, once completed, gyro is ready for use.
Reset(Travel Restore Default Setting)
Press the switch to power on to travel set mode, hold switch 3 seconds, red light and yellow-green flash alternately. Restore to default after 2 seconds. Then enter into initialization, once the initialization process hase been completed, the gyro is ready for use.
Gyro Direction(Forward and Reverse Gain Setting)
In the normal working state, hold press switch 4 seconds, orange light slow flash 3 times, reverse gain direction.
Dual Gain Mode Set
In the normal working state, fast press switch 2 times, red slow flash 3 times, change normal mode/sensitive mode.