Specification:
Temperature Range: -50~110°C
Resolution: 0.1 (9.9~99.9), 1 (other)
Temperature Control Mode: On/Off
Temperature Control Accuracy: 0.1
High Temperature Protection: 0-110
Refresh Frequency: 0.55s
Return Difference Accuracy: 0.1
Input Voltage: DC 12V
Output: 10A One-Channel Relay
Static Current: 35MA
Suction Current 65MA
Environmental Requirements: -10 ~ 60, 20%-85% RH
Instructions:
Long press SET for 5s to get menu, starts at P0, press +/- to get next P-parameter, press set to determine the P-parameter, press +/- to set the desired value for the selected parameter, press SET to accept it, long press +/- reset to default
Indicator & Digital Tube Status Description:
Indicator: Off - The relay is disconnected, ON - The relay is closed
Digital Tube: Display LL - Sensor open circuit; Display HH - Exceed the measuring range, the temperature controller will force the relay to disconnect; Display ----- - High temperature protection
Parameter Setting:
Setting Comparison Table Code Code Description Setting Range Factory Setting P0 Refrigeration/Heating C/H C P1 Return Difference Setting 0.1-15 2 P2 Maximum Setting Limit 110 110 P3 Minimum Setting Limit -50 -50 P4 Temperature Correction -7.0~7.0 0 P5 Delay Start Time 0-10min 0 P6 High Temperature Alarm 0-110 OFF