Enables the technician to quickly verify if the electrodes are properly positioned
Allows the technician to conveniently adjust the electrodes to the Riello Specifications: 5mm above the center of the nozzle, 2.25mm in front of the nozzle and a 4 mm gap between the electrode tips (The burner manufacturer instructions permit position the electrode tips from 2mm to 2.5mm in front of the nozzle)
Sets the electrodes on the drawer assembly with or without the turbulator disc (retention head) on
Description
- Enables the technician to quickly verify if the electrodes are properly positioned / - Allows the technician to conveniently adjust the electrodes to the Riello Specifications: 5mm above the center of the nozzle, 2.25mm in front of the nozzle and a 4 mm gap between the electrode tips (The burner manufacturer instructions permit position the electrode tips from 2mm to 2.5mm in front of the nozzle) / - Sets the electrodes on the drawer assembly with or without the turbulator disc (retention head) on