Search

5V - 24V Motor Forward/Reverse Controller Timing Delay Time Cycles Relay

KWD 6.500

Brand
Walfront
Weight
46 g
1 +

Special Features

  • This is a multi-function DC/AC motor forward and reverse controller with multiple control modes. Many control functions can be derived through reasonable settings.
  • Dual power supply (two power supplies cannot be powered at the same time): Power supply 1, DC 6.5-25V; Power supply 2, DC 5V.
  • Working current: (Normal Mode) standby current 41mA, working current 83mA; (Energy-Saving mode) Standby current 7mA, working current 44mA. Relay load current, recommended less than 5A.
  • There are three input control port: forward control(FWD), reverse control(), and stop control(STOP).
  • Two input trigger modes: Low-Pulse trigger mode and Low- trigger mode, Delay time: 0.1-999.9 seconds, 1-9999 seconds, 1-9999 minutes. Cycle times: no cycle, 2-99 cycles, always cycle.

Description

Port:
DC 5.5MM female : Power supply 1, DC 5V power supply.
VIN: Power 2 positive, DC 6.5-25V power supply
GND: Power supply 2 negative
FWD: Forward input control (partial Function-Mode is invalid)
: Reverse input control (partial Function-Mode is invalid)
STOP : Stop input control (partial Function-Mode is invalid)
M+: Motor positive
M-: Motor negative
P+: Positive terminal for motor power supply
P-: negative terminal for motor power supply

Specification:
Power supply: DC 6.5-25V, DC 5V
Working current: 83mA
Standby current: 41mA
Relay load current: Delay time: 0.1-999.9 seconds, 1-9999 seconds, 1-9999 minutes
Size: 8*5cm/3.2*2in
Weight: Approx. 51g/1.8oz

Trigger mode:
1 low pulse trigger (falling edge trigger)
2 low trigger (rising edge trigger)

Timer:
T1: Forward timer
T2: Reverse timer
T3: Stop timer
Time unit : 0.1 second, 1 second, 1 minute

Relay action:
Motor forward : Relay 1 is ON, relay 2 is OFF, and the F LED indicator is flashing.
Motor reverse : Relay 1 is OFF, relay 2 is ON, and the R LED indicator is flashing..
Motor stop : Relay 1 is OFF, relay 2 is OFF, and the S LED indicator is flashing.

Factory settings:
Press the ++ and -- buttons simultaneously for 5 seconds.

Energy-saving mode:
Press and hold the OK button for 5 seconds to enter the Energy-saving mode. Press and hold the OK button again for 5 seconds to exit the Energy-saving mode. Energy saving mode just turns off the digital tube and LED indicator, and other functions are normal.

Package list:
1 x Motor Controller board

Related Items


{"error":"Error","cart_limit":"You have too many items in your cart.","prod_limit":"You cannot add any more of this item"}