Description

Specification:
This module is mainly used for measuring DC voltage, current, active power, frequency and energy consumption, the module is without display function, the data is read through the RS485 interface.
Features:
It is mainly used for measuring DC voltage, current, active power, frequency and energy consumption.
The current measure range is 50A, 100A, 200A, 300A on the external shunt specification.
There are 10 different kits to choose, enough to meet your various need.
Physical layer use UART to RS485 communication interface, baud rate is 9600, 8 data bits, 2 stop bit, no parity.
The application layer use the ModbusRTU protocol to communicate, it only supports function such as 0x03, 0x04,0x06, 0x41, 0x42, etc.
Voltage threshold can be set, divide into high voltage and low voltage threshold, when the measured voltage exceeds the threshold, it can alarm.
Specification:
Brand: PEACEFAIR
Model: PZEM-017
Voltage:
Measuring Range: 0.05-300V (When the test voltage is <7V, please use the independent power supply mode)
Resolution: 0.01V
Measurement Accuracy: 1%
Current:
Measuring Range: 0.02-300A (Can be matched with 50A, 100A, 200A, 300A four kinds of shunt)
Resolution: 0.01A
Measurement Accuracy: 1%
Power:
Measuring Range: 0.2-90kW
Resolution: 0.1W
Measurement Accuracy: 1%
Energy Consumption:
Measuring Range: 0-9999kWh
Resolution: 1Wh
Measurement Accuracy: 1%
Reset Energy: Use Software to Reset
Over Voltage Alarm:
Default High Voltage Threshold: 300V
Default Low Voltage Threshold: 7V
Communication Interface: RS485 Interface
Working Temperature: -20~60℃
Product Size: Approx. 9*6*2.3cm/3.5*2.4*0.9inch
Weight: Approx. 77g~287g / 2.7oz~10.1oz
Register address Description Resolution
0x0000 Voltage value 1LSB correspond to 0.01V
0x0001 Current value 1LSB correspond to 0.01A
0x0002 Power value low 16 bits 1LSB correspond to 0.1W
0x0003 Power value high 16 bits
0x0004 Energy value low 16 bits 1LSB correspond to 1Wh
0x0005 Energy value high 16 bits
0x0006 High voltage alarm status 0xFFFF is alarm,0x0000 is not alarm
0x0007 Low voltage alarm status 0xFFFF is alarm,0x0000 is not alarm
Register address Description Resolution
0x0000 High voltage alarm threshold(5~350V), default is 300V 1LSB correspond to 0.01V
0x0001 Low voltage alarm threshold(1~350V), default is 7V 1LSB correspond to 0.01V
0x0002 -RTU address The range is 0x0001~0x00F7
0x0003 The current range 0x0000: 100A 0x0001: 50A 0x0002: 200A 0x0003: 300A
Optional Kit
#1 1 x DC Consumption Meter
#2 1 x DC Consumption Meter 1 x RS485 to USB Cable
#3 1 x DC Consumption Meter 1 x 50A Shunt
#4 1 x DC Consumption Meter 1 x 100A Shunt
#5 1 x DC Consumption Meter 1 x 200A Shunt
#6 1 x DC Consumption Meter 1 x 300A Shunt
#7 1 x DC Consumption Meter 1 x RS485 to USB Cable 1 x 50A Shunt
#8 1 x DC Consumption Meter 1 x RS485 to USB Cable 1 x 100A Shunt
#9 1 x DC Consumption Meter 1 x RS485 to USB Cable 1 x 200A Shunt
#10 1 x DC Consumption Meter 1 x RS485 to USB Cable 1 x 300A Shunt
Note:
RS485 interface is passive output, need external connect 5V power supply and the external power supply should >100mA.
When the input test voltage is less than 7V, it must supply 5V independent work voltage through USB port.
Do NOT use the USB port bring by your PC to be the independent power supply, otherwise it may damage your PC.

Related Items


{"error":"Error","cart_limit":"You have too many items in your cart.","prod_limit":"You cannot add any more of this item"}