The general purpose guard capacitance point level switch provides reliable high or low liquid level detection of water based conductive liquids with light coating, crystallizing or scaling characteristics with a 1A relay output. Media examples include copper sulfate and brine. The RF guard circuit eliminates the coating signal path between the active and reference electrodes. The submersible polypropylene liquid level sensor is universally mounted through non-metallic tank walls or inside the tank as a high level alarm or low level alarm. Ideal for coating liquids. Great for waste water applications. Orientation: universal. Accuracy: +/- 1mm in water. Repeatibility: +/- 0.5mm in water. Dielectric range: > 20 constants. Conductive range: > 100 micro. Supply voltage: 12-36 VDC. Consumption: 25 milliampere maximum. Contact type: (1) SPST relay. Contact rating: GP: 60 VA 1A maximum. Contact output: selectable NO/NC. Process temprature: -40 to 176 degreeF. Pressure: 150 psi at 25 degreeC, derated at 1.667 psi per degreeC above 25 degreeC. Sensor rating: NEMA 6 (IP68). Sensor material: polypropylene. Cable jacket material: polypropylene. Cable type: 4-conductor, shielded. Cable length: 10'. Process mount: 3/4" NPT. Mount gasket: Viton. Classification: general purpose. Compliance: CE.