Specification:
Resolution Ratio: -9.9-99.9--0.1 other temperature intervals--1
Control Precision: 0.1
Return Difference Precision: 0.1
Refresh Rate: 0.5 S
High-temperature Protection: 0-110
Measurement Input: NTC (10K 0. 5%) waterproof sensor
Output: 20A Relay
Environmental Requirements:
Temperature Requirement: -10 ~60
Humidity Requirement: 20%-85%
Machine Power Consumption: static current 35MA, pickup current 65MA
Methods of Use:
1. After Connecting to the power supply and load (referring to the wiring diagram), you can supply power for the controller, the color red manifest for measuring temperature, the following color blue (or red) as required to set the temperature
2. In the case of manifesting real temperature and please press the button set, the following setting text digital will flash and temperature, after completing the setting, please wait for 3 it will return automatically, at this time controller will automatically disconnect Relay according to the preset temperature, the this senor can meet all kinds of large power load, please make sure the line is correct
Code Explain Setting range Factory setting
P0 Heating/cooling H/C C
P1 Return difference 0.1-30 2.0
P2 Set limit maximum + 110 110
P3 Set limits to the minimum -50 -50
P4 Temperature correction -15-15 0
P5 Delay start 0-10 0
P6 High temperature alarm -50~110 OFF
P7 CS/FH cs
F8 Factory Reset ON-OFF OFF