Specifications:
Load supply voltage: DC 5.0V
Load supply current: Less than or equal to 200mA
Load input voltage: DC 1.5V-25V
Load input current: 0.00A-4.00A(4A/25W),0.00A-5.00A(5A/35W)
Voltage accuracy: 1% (can be calibrated)
Current accuracy: 1% (can be calibrated)
Digital heat mode: intelligent temperature control fan + aluminum heat sink
Fan speed: 6000rpm(4A/25W),8000rpm(5A/35W)
Working environment temperature: -15℃-50℃
Undervoltage protection LVP threshold: default 1.5V(Adjust between 1.5-24.5V)
Overvoltage protection OVP threshold: default 25.0V(Adjust between 1.5-25V)
Overcurrent protection OCP threshold:default 4.1A(4A/25W,Adjust between 1-4.1A) ,default 5.1A(5A/35W,Adjust between 1-5.1A)
Over-power protection OPP threshold: default 25.5W(4A/25W,Adjust between 1-25.5W),default 35.5W(5A/35W,Adjust between 1-35.5W)
Over temperature protection OTP: default 80℃(Adjust between 40-80℃)
Size: 114*43*30mm, weight: 45g
Automatic statistics of discharge capacity and discharge time:
Turn on the load and start statistics when the RUN indicator is always on, turn off the load, and stop statistics when the RUN indicator is off. Statistical data supports power-down storage. If you need to clear the statistical data, when the discharge capacity or time is displayed on the LCD screen, long press the button "Minus sign". The maximum discharge capacity (OAH) and maximum discharge time (OHP) can be set on or off in the setting mode (default off). After being turned on, the threshold value can be set. If the threshold value is exceeded, the load will be automatically turned off to realize unattended discharge experiment.
Package Includes: 1pcs