INSTRUCTION FOR USE Dear Customer, We kindly ask you to read carefully the following instruction before handling and using the instruments. Each instrument has been realized with great care and professionalism and its use is addressed only to Qualified and dental specialized personnel. 1. INITIAL USE: The instrument is supplied 'NON-STERILED'. It must be properly washed, rinsed and sterilized before to be used. Many joint instruments present oily residuals in the parts, due to the manufacturing phases. Please make sure to clean the instruments into the proper way. If the use of a washing-machine is not possible, the instruments can also be washed manually '.use a rigid brush with plastic bristles (No metal bristles) and make always sure to use the proper washing and decontamination solutions. 2. STERILIZATION: It is highly recommended to sterilize the instruments only after a proper cleaning. If the instruments are not perfectly cleaned, the result of the sterilization is prejudiced. 2.1 AUTOCLAVE STERILIZATION: The main aim of the autoclave sterilization is to obtain a proper sterilization and, in the meantime, to maintain unchanged the structural and functional characteristics of the instruments as much as possible. This process must be done only and exclusively by expert personnel, that must have been properly trained for this purpose. E. Do not put together in the same trays for the washing/sterilization instruments made of different metals (ex: common steel with stainless steel, aluminum, chromed steel ...) A. Joint instruments (ex: pliers, scissors, needle -holders,...) must be Placed in and open position for the washing /disinfection. B. Possible residuals after the first wash must be completely removed. C. It has been proved that the ideal temperature for the final rinsing is between 80°C and 90°C. D. It is highly recommended to use only demineralized water during the final rinsing. This device avoids the rise up of dark stains. E.To maintain the perfect efficiency of joint instruments. It is necessary to lubricate them regularly with specific products (DO NOT USE INDUSTRIAL OILSATALL). ATTENTION :DRY HEAT STERILIZATION Aluminum and Titanium instruments. Do not put aluminum instruments and titanium instruments into thermal equipment and /or ultrasound bath. For the cleaning of these instruments and titanium. DECLINES AND RESPONSIBILITY FOR THE FOLLOWING CASES: 1. Damages caused by the warehousing of the instruments in unsuitable location. 2. Damages caused by a wrong process of cleaning and /or sterilization of the instruments. Damages caused by the lack of maintaining of the instruments, especially for the joint ones, that need a regular lubrication in the joint parts.