Siemens ECSBPK05 Generator Standby Power Mechanical Interlock

KWD 20

Brand
SIEMENS
1 +

Special Features

  • UL Listed
  • For use on Siemens or Murray panels
  • Main breaker is QNR or MD-TR type
  • Standby power breaker must be a QP or MP-T double pole breaker
  • No modification of panel required; Breakers not included

Description

Siemens standby power mechanical interlock kits provide a means to ensure that the main breaker powered by utility power within a panel is forced to the OFF position when standby power is in use. It also ensures that the standby source is forced to the OFF position when the utility power is in use. This model (ECSBPK05) is designed for use on load centers or meter combinations that will accept a QNR (MD-TR) frame circuit breaker next to a 2-pole circuit breaker. It's compatible with QNR, QNRH, and HQNR utility main breaker types and QP, QPH, and HQPH standby main breaker types.
The most common application for an interlock kits is when a portable generator is used to provide back up power to a building. If the utility main breaker in a panel is left in the -"ON"-position while a generator is powering the panel, dangerous back feeding of the utility power lines can occur.
The ECSBPK05 interlock kit (). Use on Siemens or Murray panels (). ECSBPK05 Generator Standby Power Mechanical InterlockAt a GlanceUL listed for use in most Siemens load centers and meter combinations
Remains attached to the main breakers when load center cover
Corrosion resistant finish
For use on Siemens or Murray panels
Easy assembly requiring no modifications to the load center or meter combination
Suitable for use with optional standby systems in accordance with article 702 of the National Electric Code
Siemens standby power mechanical interlock kits provide a means to ensure that the Main breaker powered by utility power within a panel is forced to the OFF position when standby power is in use. It also ensures that the standby source is forced to the OFF position when the utility power is in use. The most common application for these kits is when a portable generator is used to provide back up power to a building. If the utility Main breaker in a panel is left in the -"ON"-position while a generator is powering the panel, dangerous back feeding of the utility power lines can occur. The ECSBPK05 will work on any Siemens or Murray panel that has a QNR(H) or MD-TR(H) Main breaker. The standby power Main breaker must be a two pole, QP or MP type breaker.