APC AP8641 Rack PDU 2G/ Switched Plus/ Zero U/ 30A/ 208V Power Distribution
Superior Equipment and Data ProtectionWhy buy APC by Schneider Electric?Over the years, APC by Schneider Electric has received hundreds of awards worldwide - more than any other power protection manufacturer. Such designations have recognized APC by Schneider Electric for both its reliable solutions and its overall business performance.
Rack PDU 2G, Metered by Outlet with Switching, ZeroU, 30A, 200/208V, (21) C13 & (3) C19Metered-by-outlet Rack PDUs provide real-time remote monitoring of each individual outlet to empower IT professionals with the necessary tools for advanced data center energy management.
APC by Schneider Electric Metered by Outlet with Switching Rack Power Distribution Units (PDUs) enable advanced, user-customizable power control and individual outlet power metering. Remote outlet level controls allow power on/off functionality for power recycling to reboot locked-up equipment and to avoid unauthorized use of individual outlets. Power sequencing delays allow users to define the order in which to power up or down attached equipment. Avoid circuit overload during power recovery and extend uptime of critical equipment by prioritizing the load shedding. Current metering provides real-time remote monitoring of connected loads. Switched Rack PDUs include real power monitoring, a temperature/humidity sensor port, and locking IEC receptacles.
User-defined alarms warn of potential circuit overloads before critical IT failures occur. Users can access, configure, and control Switched Rack PDUs through secure Web, SNMP, Command Line Interface, or Telnet Interfaces which are complimented by Schneider Electric's StruxureWare solution.
AP8641 FeaturesMetering-by-Outlet capability: Individual outlet level power metering provides a more granular view of the power distributed to equipment within the enclosure. It also provides the ability to analyze component power trends and perform capacity planning.
Metered-by-Outlet Rack PDU Features & Benefits Availability Metering-by-Outlet capability Individual outlet level power metering provides a more granular view of the power distributed to equipment within the enclosure. It also provides the ability to analyze component power trends and perform capacity planning. Network Management Full-featured network management interfaces that provide standards-based management via Web, SNMP, and Telnet. Allows users to access, configure, and manage units from remote locations to save valuable time. Associated with this feature is the ability to quickly and easily upgrade the firmware via network download to installed units for future product enhancements. Remote Individual Outlet Control Remotely manage outlets so users can turn outlets off that are not in use (prevent overloads) or recycle power to locked-up equipment (minimize costly downtime and avoid travel time to equipment). Alarm Thresholds Define alarm thresholds in order to avoid overloaded circuits. Network and visual alarms inform the user of possible problems. (Note: Only available on units with the current monitoring capabilities. Please see SKU specifications for availability) Local Current Monitoring Display The aggregate current draw per power distribution unit is displayed on the unit via a digital display. The local digital display helps installers avoid overloaded circuits by providing a visible warning when the current draw is close to the maximum amperage draw of the strip. (Available on designated SKUs only) Power Delays Allows users to configure the sequence in which power is turned on or off for each outlet. This helps avoid in-rushes at start-up, which can cause overloaded circuits and dropped loads. Sequencing also allows users to predetermine which piece of equipment is turned on first so other equipment dependant on that unit will function properly. Load Indicator LED Indicates overload and warning conditions based on the user-defined alarm thresholds. Alerts users of potential overloaded circuits. Flash Upgradeable Quickly and easily upgrade firmware via network download for future product enhancements. Eliminates the need to replace products already installed in the field when new features are released. (Note: Networked units only)
Technical Specifications Output Nominal Output Voltage 208V Maximum Total Current Draw per Phase 30A Output Connections (21) IEC 320 C13 (3) IEC 320 C19 Overload Protection Yes Input Nominal Input Voltage 208V Input Frequency 50/60 Hz Regulatory Derated Input Current (North America) 24A Input Connections NEMA L6-30P Cord Length 3 meters Number of Power Cords 1 Acceptable Input Voltage 200-240 VAC Maximum Line Current per phase 30A Maximum Input Current per phase 30A Physical Net Weight 8.23 kg Maximum Height 1829.00 mm Maxiumum Width 56.00 mm Maximum Depth 51.00 mm Shipping Weight 10.50 kg Shipping Height 2038.00 mm Shipping Width 162.00 mm Shipping Depth 118.00 mm Color Black Units per Pallet 42.00 Environmental Operating Environment -5 - 45 °C Operating Relative Humidity 5 - 95% Operating Elevation 0 - 3000 meters Storage Temperature -25 - 65 °C Storage Relative Humidity 5 - 95% Storage Elevation 0 - 15,000 meters Conformance Regulatory Approvals cUL Listed, FCC Part 15 Class A, ICES-003, UL Listed, VCCI Class A Standard Warranty 2 years repair or replace Sustainable Offer Status RoHS Compliant