Product introduction:
1. Operating voltage: 4-28V
2. Operating current: 2.8mA (typical); 3mA (max)
3. Detection distance: 5-7m
4. Transmission power: 20mW (typical); 30mW (max)
5. Output voltage: 3.2-3.4V
6. Output voltage driving capacity: 100mA
7.Trigger Way: Repeat trigger
8.Output control low level: 0V
9.Output Control High Level: 3.3V
10. Operating temperature: -20 ~ 80 Celsius
11. Storage temperature: -40~100 Celsius
Setting part Introduction:
1.C-TM
Repeat Adjust trigger time, default trigger time is 2s; Increasing capacitor capacity will make repeat trigger time longer; and actual count trigger time can work as follows: stick capacitor on C-TM, test 9196 3-pin frequency F, repeat trigger time T=(1/f)* 32768
2.R-GN
Detection distance adjustment; Connection with resistance and detection distance becomes shorter; if not, the detection distance is 7 m; When connected with 1 M Ohm resistance, the detection distance is 5 m
3.R-CDS
Internal VCC parallel port with internal 1M ohm resistor to CDS pin (i.e. 196 9 pin) via R-CDS, CDS port with photoresistor, you can close the detection function at night
Package included:
3 x RCWL-0516 Microwave Radar Sensor Smart Switch Module Human Body Induction Module 4-28V 100mA