12 or 24 VDC input power, 2 dedicated digital inputs for tamper and power failure status
RS-485 communication, multidropped (2-wire or 4-wire RS-485)
Up to 16 OCMs per Intelligent System Controller
On-board termination jumpers
DIP switch-selectable addressing
Status LEDs for communication to the host, heartbeat and relay status
Elevator control, support for 128 floors
Suitable as replacement for Series 1 and Series 2 boards
Description
Series 3 LenelS2 Output Control Module (OCM) communicates directly with the Intelligent System Controller (ISC) by either 2-wire or 4-wire RS-485 communication. Each OCM is an individually-addressed device, and counts as a single device on all Intelligent System Controllers. The OCM can be operated by either 12 or 24 VDC power. Each OCM includes dedicated tamper and power failure input contacts. The OCM has 16 programmable output relays that can be configured for fail-safe or fail-secure operation. Each relay supports the “On,” “Off,” and “Pulse” OnGuard software commands.